WILO  Art.Nr: 15472201826635

WILO Wilo Smart Pump Stratos MAXO-D 32/0.5-12 PN6/10 (DE) – 2186225

Regular price
Regular price € 4.152,10 inkl. USt.
€ 3.460,08 exkl. USt.
Verfügbarkeit wird geladen …
WhatsApp Sofortberatung Jetzt online Persönliche Beratung direkt vom Fachmann – Antwort meist in wenigen Minuten.

Premium Smart Pump Wilo-Stratos MAXO-DH High-efficiency inline glandless twin pump with EC motor and electronic power adjustment. Can be used for heating water, cold water, and water-glycol mixtures. Energy efficiency index (EEI) between ≤ 0.17 and ≤ 0.19 depending on the pump type. Control modes: Permanent, automatic power adjustment to system requirements without setpoint specification Wilo-Dynamic Adapt plus (factory setting). Up to 20% energy saving compared to dp-v control mode. Constant temperature (T-const.) Constant differential temperature (dT-const.) Demand-driven volume flow optimisation of the feeder pump through networking and communication with multiple pumps (Multi-Flow Adaptation). Constant volume flow (Q-const.) Differential pressure control dp-c at a remote point in the pipe network (worst point control) Constant differential pressure (dp-c) Variable differential pressure (dp-v) with the option of nominal operating point input Constant speed (n-const.) User-defined PID control Functions: Heat quantity acquisition Cooling quantity acquisition Automatic pump shut-off upon zero-flow detection (No-Flow Stop) Switching between heating and cooling operation (automatic, external or manual) Adjustable volume flow limitation by Q-Limit function (Qmin. and Qmax.) Twin pump operating modes: Efficiency-optimized additive operation for dp-c and dp-v, main/standby operation Save and restore configured pump settings (3 restore points) Fault message/warning message display in plain text including recommended remedies Ventilation function for automatic venting of the rotor chamber Automatic night setback Automatic deblocking function and integrated full motor protection Dry-running detection Display: Control mode Setpoint Volume flow Temperature Power consumption Electrical consumption Active influences (e.g. STOP, No-Flow Stop) Design: 2 configurable analog inputs: 0-10 V, 2-10 V, 0-20 mA, 4-20 mA and commercial Pt1000; power supply with +24 V DC 2 configurable digital inputs (Ext. OFF, Ext. Min, Ext. Max, Heating/Cooling, Manual Override (building automation disconnected), Operation Lock (keypad lock and remote control configuration protection)) 2 configurable signal relays for operation and fault messages Slot for Wilo-CIF modules with interfaces for building automation BA (Optional accessories: CIF modules Modbus RTU, Modbus TCP, BACnet MS/TP, BACnet IP, LON, PLR, CANopen) Wilo Net as Wilo system bus for communication between Wilo products, e.g. Multi-Flow Adaptation; twin pump operation and Wilo-Smart Gateway Integrated temperature sensor Automatic emergency operation in special conditions (pump speed definable) e.g. in case of bus communication failure or sensor value failure Graphical color display (4.3 inches) with operation via single-button manual control level Reading and setting operating data and e.g. creating a commissioning report via Bluetooth interface (without additional accessories) using the Wilo Assistant App Twin pump management integrated (twin pumps are pre-wired), when using 2 single pumps as a twin pump unit, connection via WILO Net Cable break detection for analog signal (in conjunction with 2-10 V or 4-20 mA) Outdoor installation with weather protection possible according to installation and operating instructions Date and time preset 5 years warranty Scope of delivery Pump 2x Optimized Wilo-Connector for all sizes 4x cable glands M16 x 1.5 Washers for flange screws M12 and M16 (for connection nominal widths DN 32 to DN 65) 2x seals for threaded connection Installation and operating instructions (digital) Optional accessories: CIF module: Modbus TCP, Modbus RTU, BACnet IP, BACnet MS/TP, LON, PLR, CANopen Pt1000 (B) pipe clamp sensor (for domestic hot water) Pt1000 (AA) sensor for installation in immersion sleeve Differential pressure sensor Operating data Fluid: Water, ethylene glycol, propylene glycol Min. fluid temperature: -10 °C Max. fluid temperature: 110 °C Min. ambient temperature: -10 °C Max. ambient temperature: 40 °C Maximum operating pressure: 10 bar Minimum inlet head at 50°C: 3 m Minimum inlet head at 95°C: 10 m Minimum inlet head at 110°C: 16 m Motor data Energy efficiency index (EEI): 0.19 Mains connection: 1~230 V ±10%, 50/60 Hz Current (min): 0.11 A Current (max): 1.42 A Motor rated power: 266 W Speed min.: 750 rpm Speed max.: 4400 rpm Power consumption: 7 W Power consumption: 320 W Emissions: EN 61800-3;2004+A1;2012 / Residential (C1) Immunity: EN 61800-3;2004+A1;2012 / Industrial (C2) Insulation class: F Protection class: IPX4D Cable gland: 5 x M16x1.5 Materials Pump housing: Cast iron Impeller: PPS-GF40 Shaft: 1.4122, DLC-coated Bearings: Carbon, antimony-impregnated Installation dimensions Suction side pipe connection: DN 32 Pressure side pipe connection: DN 32 Installation length: 220 mm Ordering information Manufacturer: Wilo Net weight approx.: 21 kg Article number: 2186225

Installation anfragen
Montage • Elektro • Inbetriebnahme
Wir bieten die Installation deiner Photovoltaikanlage durch unser Team sowie durch ausgewählte Partnerbetriebe an. Gemeinsam sorgen wir für eine fachgerechte Montage, Elektroinstallation und zuverlässige Inbetriebnahme.
Installation anfragen

Technische Parameter

Produkteigenschaften ETIM

Ursprungsland
DE
Zolltarifnummer
84137030
eClass
36410111
eClass Bezeichnung
Einbau-Umwälzpumpe
ETIM-Klasse
Umwälzpumpe
Werkstoff des Pumpengehäuses
Gusseisen
Werkstoff des Gehäuses
Gusseisen
Werkstoffgüte des Pumpengehäuses
Gusseisen GG 25 (GJL-250)
Werkstoff des Gebläserads/Laufrads
Polypropylen (PP)
Werkstoffgüte
Gusseisen GG 25 (GJL-250)
Werkstoffgüte Gebläserad/Laufrad
PP-GF
Volumenstrom (BEP)
8.21 m³/h
Förderhöhe bei Volumenstrom (BEP)
77.8 kPa
Max. Volumenstrom
23.46 m³/h
Max. Förderhöhe
12.7 m
Max. Arbeitsdruck
10 bar
Nenndurchmesser
DN 32
Doppelpumpe
Ja
Bemessungsspannung
230 - 230 V
Anschluss
Flansch
Anzahl der Phasen
1
Druckstufe Artikel
PN 10
Frequenz
50/60 Hz
Nennstrom
1.42 A
Druckstufe Flansch
PN 6/10
Aufgenommene Motorleistung (P1) pro Motor
0.32 kW
Energieeffizienzindex (EEI)
0.19
Isolationsklasse nach IEC
F
Anschlussspannung
1x 230 V
Drehzahlregelung Motor
eingebaut
Leistungsaufnahme der Pumpe (solpump)
320 W
Leistungsaufnahme der Pumpe im Bereitschaftszustand (solstandbypump)
7 W
Max. Mediumtemperatur (Dauerbetrieb)
110 °C
Min. Mediumtemperatur (Dauerbetrieb)
-10 °C
Länge Anschluss 1
110 mm
Länge Anschluss 2
85 mm
Unterstützt Protokoll für LON/LONWorks
Ja
Mediumtemperatur (Dauerbetrieb)
-10 - 110 °C
Umgebungstemperatur
-10 - 40 °C
Anschluss Einlassseite
Flansch
Anschlussmaß Pumpengehäuse
DN 32
Nenndurchmesser, Anschluss Einlassseite
DN 32
Rohraußendurchmesser, Anschluss Einlassseite
32 mm
Druckstufe Flanschanschluss Einlass
PN 6
Anschlussstandard Einlassseite
EN 1092-2
Anschluss Auslassseite
Flansch
Nenndurchmesser, Anschluss Auslassseite
DN 32
Rohraußendurchmesser, Anschluss Auslassseite
32 mm
Druckstufe Flanschanschluss Auslassseite
PN 6
Anschlussstandard Auslassseite
EN 1092-2
Flanschform
rund
Einbaulänge
220 mm
Schutzart (IP)
IPX4D