PANASONIC Panasonic Heat Pump R290 Aquarea L Air/Water HP, 5 kW, Outdoor Unit – WH-WDG05LE5
€ 3.291,74 exkl. USt.
PANASONIC Panasonic Heat Pump R290 Aquarea L Air/Water HP, 5 kW, Outdoor Unit – WH-WDG05LE5 is backordered and will ship as soon as it is back in stock.
Panasonic Hydro Split Heat Pump Aquarea, single-phase, inverter-controlled, R290
Hydro module
Hydro module for air/water heat pump in HydroSplit design, 230 V and 185 L hot water tank
Operating modes: Heating, hot water, cooling (cooling operation can be activated via setting)
Outdoor unit
Outdoor unit for air/water heat pump in split design, 230 V, R290
Housing made of galvanized and stove-enamelled sheet steel RAL 7016, for outdoor installation, removable housing cover for easy access to internal components. Base plate with mounting lugs and condensate opening.
Axial fan with enlarged fan diameter for constant air flow to reduce fan speed and saw-blade tips on the fan blades to minimize turbulence. Driven by a continuously variable DC motor and a sound and flow-optimized plastic impeller. Tightly mounted control box at the top for safe water discharge, gas/liquid separator. Factory tested for pressure resistance and leak tightness and pre-filled with environmentally friendly refrigerant.
Complies with design regulations according to IEC 60335-2-40: 2022. Heat exchanger made of copper pipes with pressed-on Bluefin-coated aluminum fins. 4-pole synchronous motor compressor, 4-point vibration damper device and soundproof compressor material to reduce vibrations and noise. Electronic expansion valve, 4-way reversing valve, filter dryer and shut-off valves with test connection.
Long pipe lengths up to 30 m and height differences up to 10 m between indoor and outdoor unit are permissible.
Hydraulic circuit
Stainless steel plate heat exchanger. Circulating pump as Panasonic high-efficiency pump with DC motor, continuously controlled. Flow monitoring. Vortex flow meter for dynamic adjustment of the water volume flow depending on the specified temperature difference, integrated dirty water magnetic filter for the water circuit, electric heating element with thermal overcurrent release. Safety and vent valve, water pressure sensor for measuring system pressure. 10-liter expansion tank. Flow temperatures up to 75 °C possible and achieved even at -10 °C outdoor temperature. Even at an outdoor temperature of -20 °C, a water outlet temperature of 55 °C is reached. The minimum water outlet temperature in cooling mode is 5 °C. Heating operation down to -20 °C, cooling operation up to +10 °C outdoor temperature possible. Particularly safe due to hydraulic connection to the indoor unit and separation of refrigerant in the outdoor unit and electronics in the indoor unit.
Control
Modulating power adjustment of the compressor through (INVERTER+) control technology.
Energy efficiency through operation start in partial load range and demand-controlled frequency increase. Temperature sensors for outdoor temperature, compressor, hot gas and suction line temperature as well as evaporator temperature. Circuit reversal for rapid and efficient defrosting of the outdoor unit heat exchanger. Communication modules for optimal data exchange with the hydro module.
Separate heating and domestic hot water control with a clear control panel. Easy-to-understand symbols and plain text menu displays in 26 different user languages. Continuous display of outdoor and flow temperature. Outdoor temperature-controlled adjustment of the flow temperature in heating mode. Temperature sensors for condenser, flow and return temperature. Display of system pressure, weekly timer for time-dependent on/off switching and operating mode selection. Programmable timer for thermal disinfection. Demand-dependent control of the electric auxiliary heater.
Further functions: Automatic operation (heating/cooling), holiday mode, screed drying program, power consumption display, improved defrost function.
Self-diagnosis system with display of error codes. Communication modules for optimal data exchange with the outdoor unit.
Optional board for additional functions such as Smart Grid control, power control via 0-10 V signal, control of two heating circuits including heating circuit pumps and mixing valves, solar thermal, external switching between heating and cooling. Optional Smart Cloud Adapter.
Setting for prioritization in silent operation possible, so that a certain volume is not exceeded.
External connection options:
-Optional board for additional functions
-Control input for external on/off switching
-Control input for external room thermostat
-Control output for 2-way valve (cooling operation)
-Control output for 3-way valve (heating / domestic hot water)
-Interface for communication with the Panasonic Smart Cloud
Electrical equipment:
-Electric auxiliary heater
-Thermal overload protection for electric auxiliary heater
-RCD control inputs and outputs
Conformity with EU directives
The device complies with the relevant EU directives and standards.
Technical data
Heating capacity / COP (A7/W35) 5 kW / 5.05
Heating capacity / COP (A7/W55) 5 kW / 3.07
Heating capacity / COP (A2/W35) 5 kW / 3.52
Heating capacity / COP (A2/W55) 5 kW / 2.34
Heating capacity / COP (A-7/W35) 5 kW / 3.01
Heating capacity / COP (A-7/W55) 5 kW / 2.12
Cooling capacity / EER (A35/W7) 5 kW / 3.23
Cooling capacity / EER (A35/W18) 5 kW / 5
Seasonal space heating energy efficiency (ηs,h), moderate climate, W35 / W55 200 % / 142 % SCOP 5.06 / 3.63
Energy efficiency class heating, moderate climate, scale: A+++ to D, W35 / W55 A+++ / A++
Seasonal space heating energy efficiency (ηs,h), warmer climate, W35 / W55 237 % / 168 % SCOP 6 / 4.07
Energy efficiency class heating, warmer climate, scale: A+++ to D, W35 / W55 A+++ / A+++
Seasonal space heating energy efficiency (ηs,h), colder climate, W35 / W55 164 % / 116 % SCOP 4.18 / 2.98
Energy efficiency class heating, colder climate, scale: A+++ to D, W35 / W55 A++ / A+
Outdoor unit WH-WDG05LE5
Sound power level (partial load, ErP, A7/W55) Heating dB(A) 52
Sound power level (full load, ErP) Heating / Cooling dB(A) 57 / 61
Dimensions / Net weight H x W x D mm / kg 996 x 980 x 430 / 98
Pre-filled refrigerant quantity (R290) / CO2 equivalent kg / t 0.96 / 0.003
Pipe diameter liquid line / suction gas line mm 20
Pipe length (max.) at -25°C m 30
Height difference ID/OD (max.) m 10
Operating range outdoor temperature °C –25 / +43
Water outlet temperature Heating / Cooling °C 20 – 75 (above -10°C ambient temperature) / 5 – 20